N: 90 S: -90 E: 180 W: -180
Description
The Copernicus Sentinel-5 Precursor (Sentinel-5P or S5P) satellite mission is one of the European Space Agency's (ESA) new mission family - Sentinels, and it is a joint initiative between the Kingdom of the Netherlands and the ESA. The sole payload on Sentinel-5P is the TROPOspheric Monitoring Instrument (TROPOMI), which is a nadir-viewing 108 degree Field-of-View push-broom grating hyperspectral spectrometer, covering the wavelength of ultraviolet-visible (UV-VIS, 270nm to 495nm), near infrared (NIR, 675nm to 775nm), and shortwave infrared (SWIR, 2305nm-2385nm). Sentinel-5P is the first of the Atmospheric Composition Sentinels and provides measurements of ozone, NO2, SO2, CH4, CO, formaldehyde, aerosols and clouds at high spatial, temporal and spectral resolutions. Spatial resolution is 5.5 km along-track and 3.5 km across-track at nadir. S5P is in a sun-synchronous orbit with an ascending node of ~13:30 which provides daily global coverage of the sun-lit Earth. Data are archived in enhanced netCDF-4 format. Beginning August 6th in 2019, S5P implemented along-track high spatial resolution (~5.5km at nadir). The near-real-time (NRT) data are generally available within three hours of measurement as required by the Land Atmosphere NRT Capability Earth Observing System (LANCE). Data granules are in five-minute intervals of an orbit, rather than a full orbit as provided for the standard products. NRT data are only archived for five days and not considered to be science-quality data. The data are intended for rapid turnaround assessments, for rigorous scientific analyses users should use the standard Version 3 product.
The TROPOMI UV Aerosol Index is calculated from wavelength dependent changes in Rayleigh scattering in the UV spectral range where ozone absorption is weak. A residual value is calculated from measured top-of-atmosphere (TOA) reflectance and per-calculated theoretical reflectance for a Rayleigh scattering-only atmosphere given a wavelength pair. TROPOMI UVAI products use the classical wavelength pair of 340/380 nm, and the OMI chosen 354/388 nm pair for the long-term continuous AI record. In Version 3 of the retrieval algorithm, a soft calibration has been implemented to correct for AI degradation.
Product Summary
Data Center Citation
Get Help
QUESTIONS & SUPPORT
Get help with NASA Earth science data, datasets, tools, services, and metadata on the Earthdata Forum. Experienced staff in the data user community review and answer questions.
Get help on Earthdata ForumForum
Documents
USER'S GUIDE
READ-ME
ALGORITHM THEORETICAL BASIS DOCUMENT (ATBD)
GENERAL DOCUMENTATION
PRODUCT HISTORY
Get Help
QUESTIONS & SUPPORT
Get help with NASA Earth science data, datasets, tools, services, and metadata on the Earthdata Forum. Experienced staff in the data user community review and answer questions.
Get help on Earthdata ForumForum